What could be the flaring alternatives to reduce GHG emission in oil and gas sector.

Views: 259

Reply to This

Replies to This Discussion

Can not the heat generated by flaring be utilized to generate

steam and run turbines to  generate electricity.   

Dear Faisal,

The following steps would reduce the GHG emission for exploration and production division:

1.If you have a line heater / burner in your organization then you can divert the flash gases from the separator / vessels and use as a burner fuel.

2. Reduced the compressor blow down.

3.strict approval to be taken while Open flows /wells test.

4. Instead of flaring use fuel for enhanced oil recovery if any well required.

5.For power generation you can utilized.

6.Investigate the causes of repeat non-routine flaring due to this you can reduce the incidents.

I hope the above steps will help you,would appreciate if u share for the same. 

Regards,

Quaiser

We need to understand why we do flare? to reduce venting- my question is flaring alternative! Flare could be as big as the size of the flare stack - practically feasible solution for utilisation of flared gas would be appriciated.

Please note that flaring is not permamment, only in emergency and during maintenence.

Regards

Faisal

 



V.K. Raman said:

Can not the heat generated by flaring be utilized to generate

steam and run turbines to  generate electricity.   

Flaring was going on for years and years in Assam Oilfields.

I don't know the present situation.  So much of gas was 

going waste in flaring.  So, I can say, flaring was a a permanent 

arrangement.

Thanks for your input .

Have you implemented the options in any of the facility. Is it possible!

If yes , to start with please elaborate on the first one to utilise the flash gases from seperator into heater burner. 

 

Regards

Faisal

 



quaiser shakir said:

Dear Faisal,

The following steps would reduce the GHG emission for exploration and production division:

1.If you have a line heater / burner in your organization then you can divert the flash gases from the separator / vessels and use as a burner fuel.

2. Reduced the compressor blow down.

3.strict approval to be taken while Open flows /wells test.

4. Instead of flaring use fuel for enhanced oil recovery if any well required.

5.For power generation you can utilized.

6.Investigate the causes of repeat non-routine flaring due to this you can reduce the incidents.

I hope the above steps will help you,would appreciate if u share for the same. 

Regards,

Quaiser

Reply to Discussion

RSS

Paryavaran.com -online webportal to network and do business and philanthropy with Indian Environment Organizations and Professionals


Notes

Network of Indian Environment Professionals LLC

Created by Chandra Kishore Feb 5, 2010 at 3:22pm. Last updated by Chandra Kishore Jan 20, 2020.

Notes Home

Created by Chandra Kishore Oct 5, 2009 at 3:19pm. Last updated by Chandra Kishore Apr 29, 2011.

© 2024   Created by Chandra Kishore.   Powered by

Badges  |  Report an Issue  |  Terms of Service