Dear Dash, recheck your activation steps. There should not be any problem. Send detailed steps so that problem can be understood.
Dear
as i seeing the COD BOD ratio of the effluent is 0.25, hence the system will not work properly.
i can give you better solution if you could send the water balance and volume of waste water.
as we all know the biological system has its own limitation to treat the waste water.
some small modification in treatment process will solve the your problem
Dear sir
we have commissioned the same type plant successfully and there was good growth of Bio mass. you have mention that there are 2 aeration tank. The flow considered for is 16.25 m3/hr for aeration tank I & for is 8.75 m3/hr for aeration tank II. why this flow variation if these aeration tanks are in series. kinldy share the following information.
what is the dissolved oxygen in the aeration tanks.
what is the reduction in the BOD level from each aeration tank outlet.
have you check the nitrogen and phosphorus level in the inlet.
what is the sludge recycle ratio in each aeration tank.
what is the volume of each aeration tank.
have you check the nutrient level in the inlet.
Dear sir
Sorry to reply late.
In this type of effluent the COD reduction in the aerobic treatment is much less then BOD reduction generally up to 30-35%.
You are getting the COD reduction 10% it mean you are getting BOD reduction is also less but it is confirm that there is BOD reduction from your system. How Much?
Reduction of BOD is showing the presence of BOD mass in your system.
Now problem is why you are not getting Bio Mass in your analysis.
There may be several reasons. Please check.
You are using Jet aeration. The numbers, capacity and configuration of Jet are as per the design. What is the influence area of aeration? Are there many dead zones in the aeration tank?
Is there floc loss from the clarifier? Is clarifier mechanism is in service and working fine.
What is the size of clarifier, aeration tank capacity of aeration system? Have you measure the DO in dead zones also. How much PPM of nitrogen and phosphorus in inlet.
Is there continuous sludge recirculation. What is MLSS level in PPM and also as SV.
Kindly collect these information so that system can be review. You can also write me at vin_saini@hotmail.com
thank you
Paryavaran.com -online webportal to network and do business and philanthropy with Indian Environment Organizations and Professionals
Join us as Institutional Member today
Organizations where our Members Come from: More than 2000 at the last count...
_______________
Organica Biotech joins us as a Diamond Institutional Member. Check Here
LEAD INDIA joins us as Diamond Institutional member. Check here
_______________
ERM joins as Partner. Invites you as India Business Partner
Envitrans Infosolutions Pvt. Ltd.
--------------------
Created by Chandra Kishore Feb 5, 2010 at 3:22pm. Last updated by Chandra Kishore Jan 20, 2020.
Created by Chandra Kishore Oct 5, 2009 at 3:19pm. Last updated by Chandra Kishore Apr 29, 2011.
© 2024 Created by Chandra Kishore. Powered by