Dear IENs Good Morning What would be criteria and Frequency for AAQ Monitoring in Power Plant.As in our EC it has been mentioned the it shall be moniored regularly but regularly means what ,should we follow the NAAQ 2009

Views: 335

Comment

You need to be a member of Indian Environment Network to add comments!

Join Indian Environment Network

Comment by DAA on May 8, 2012 at 1:09am

As you earlier stated that, you are having online stack gas and AAQM monitoring system.Will you please share information on online AAQM monitoring system?of which company?

Comment by Pravin M. Jadhav on May 5, 2012 at 6:43am

Dear Himanshu

You need to installed three AAQM Monitoring stations as per wind direction one at Upwind and two at downwind direction (on 120 degree angle triangle).

Frquency as per NAAQS 2009 104 readings at each locations means you have to monitor one location twice a week.

Again all parameter analysis is very costly so you can monitor SOx, NOx, ammonia, Ozone, PM2.5 PM 10 for 104 reading at one location and once in month or qtrly you can grab the sample for metal, Benzene, bezo pyerene.

I think this will help you to monitor air quality better.

You can increase the frequency of sampling if these parameters found to be higher than specified limits and after taking corrective action.

Hope this data will help you.

Regards,

Pravin M Jadhav

Comment by Rangan Chakraborty on May 4, 2012 at 7:33am

For the purpose to know the frequency of monitoring follow the gude line in EPA-1986 & try to follow the NAAQ 2009 standard only

 

Comment by HIMANSHU VERMA on May 4, 2012 at 3:13am

We are already having Continuous online Stack and ambient monitoring system in this case what we are suppose to do

 

 

Comment by ganesan viswanathan on May 4, 2012 at 2:12am

The Env Protection Act / Rules prescribes for all large scale (highly polluting industries) industries shall carried out The AAQ Survey twice ina week and in certain cases contineous monitoring is also suggeted based on the public complaints

Comment by dr. hitesh sukhwal on May 3, 2012 at 10:59pm

Absolutely AAQM should follow as per NAAQS 2009 norms 104 nos. in the year and twice in a week.

 

Regards

 

Dr Hitesh

Comment by Harendra Tomar on May 3, 2012 at 7:49am
Follow NAAQS 2009
Comment by adhikrao yewale on May 3, 2012 at 7:33am
as per the cpcb guidlines
Comment by Sudipto Ghosh on May 3, 2012 at 6:23am

Yes, that should be the case.

 

Warm regards

 

Sudipto

Comment by Dr. Satendra K Jain on May 3, 2012 at 6:15am

If frequency and duration is not defined in EC , follow Consents and if it is not defined in Consents also. I think u need to follow NAAQS-2009.

 

Regards

 

Paryavaran.com -online webportal to network and do business and philanthropy with Indian Environment Organizations and Professionals


Notes

Network of Indian Environment Professionals LLC

Created by Chandra Kishore Feb 5, 2010 at 3:22pm. Last updated by Chandra Kishore Jan 20, 2020.

Notes Home

Created by Chandra Kishore Oct 5, 2009 at 3:19pm. Last updated by Chandra Kishore Apr 29, 2011.

© 2024   Created by Chandra Kishore.   Powered by

Badges  |  Report an Issue  |  Terms of Service